Defects engineering by specific doping and irradiation technologies is one of the trends in improving and modifying of specific parameters of semiconductors devices. It is known that Ge doping of Si during the Czochralski (CZ) growth process has a beneficial effect on strength of Si wafers and thus on reduction of dislocation nucleation [1]. Also, introduction of Ge into Si has additional advantages because it is isovalent impurity and do not introduce electrically active deep centres. Therefore, it is a promising dopant for the expedient manipulation of the internal gettering capacity [1]. Ge doping above 1020 cm-3 leads to the formation of germanium clusters acting as gettering centres for the intrinsic point defects. The effect of germanium doping has the important consequences for radiation-induced defect formation and population dynamics. [1-2]. It is also known that Ge doping suppresses formation of thermal donors [2].
In this work two sets of n-type CZ grown Si diodes have been investigated, one of them with Ge doping concentration of 1019 cm-3 (GCZ) and the second one without Ge doping (CZ). P-on-n diodes were irradiated with 2 MeV electrons with fluence in the range of 1015 and 1016 e/cm2. Deep Level Transient Spectroscopy (DLTS) has been employed to identify specific defects and to evaluate density of these deep centres, of carrier capture cross-section and activation energy in order to reveal an impact of Ge doping on parameters of radiation defects. Three peaks have been observed in both sets of samples after irradiation. Electron traps corresponding to the V-O complex (the so-called A-centre), to di-vacancy and to P-V complex (E-centre) have been identified after irradiation by 1015 e/cm2 fluence of 2 MeV electrons. An amplitude of the DLTS peak attributed to V-O centre slightly increases in GCZ sample, while concentration of other defects does not depend on Ge doping. Peaks corresponding to di-vacancy and phosphorous-vacancy (P-V) complex strongly increase with electron irradiation fluence.