CHARACTERISATION OF THE Si THYRISTOR STRUCTURES BY CAPACITANCE TECHNIQUES

A. Velička1, T. Čeponis1, E. Gaubas1

1 Institute of Applied Research, Vilnius University, Saulėtekio Ave. 9-III, LT-10222 Vilnius, Lithuania

Capacitance techniques are powerful tools for detection and identification of deep level centers in layered structures of the semiconductor devices. Deep centers of considerable densities are as usually introduced during high temperature technological procedures. These defects affect the device operational characteristics. Therefore, combined investigations of the material and of functional characteristics of the devices are necessary to resolve and suppress these technological defects.

In this research, the diffusion doping introduced defects have been investigated in three layer (p-n-p) and four layer (n+-p-n-p) thyristor structures fabricated by “Vilniaus Ventos Puslaidininkiai”, by combining several techniques based on the capacitance control. Two sets of samples as A and B have been examined, - those meet the technical requirements (A) and those are inconsistent with operational limits (B), respectively.

Research has been implemented by combining the Capacitance – Voltage (C-V) and Deep Level Transient Spectroscopy (DLTS) methods. Measurements of the temperature dependent C-V characteristics have been performed using small ac signal technique implemented by QuadTech 7600 LRC meter, cryostat and external galvanic voltage source instrumentation which enabled us to reach high measurement precision. A commercial spectrometer DLS-82E has been used for DLTS spectroscopy of traps employing the temperature scan mode.

Manifestation of deep level centers in both batches of “A” and “B” samples have been revealed by C-V measurements in three-layered structures. The elevated densities of the dominant deep centers, ascribed to sulphur (S) impurities, have been resolved as S duplet peaks within DLTS spectra measured on samples “B” relatively to that of “A” ones. Moreover, it has been unveiled that samples “A” contain the compensating minority carrier traps attributed to copper (Cu3+) impurities. These deep centers appeared to be a reason for the increased leakage current and of the reduced breakdown voltage, inherent for samples “B” relatively to that in samples "A".