Power device structures are formed by employing high temperature diffusion procedures to introduce dopant atoms of certain concentrations and at proper depths. However, undesirable impurities can be introduced together with dopants as well. These impurities act as generation/recombination and trapping centers, and affect the operational parameters of power devices [1]. Furthermore, these centers may unpredictably transform under operational heating and change the parameters of power devices [2]. So, it is very important to analyze the behaviour of introduced centres after thermal treatments.
In this work, small test harmonic signal induced and pulsed [3] capacitance-voltage as well as capacitance - frequency characteristics have been examined within layered thyristor structures to evaluate an impact of deep traps on operational characteristics of devices. The pulsed technique is based on measurements and analysis of barrier capacitance current transients by applying the linearly increasing voltage pulse. Combining current transient measurements with additional illumination allows evaluating of the parameters of carrier traps and generation centres. The dopant profiles can be also evaluated by employing the modified pulsed technique [4]. The latter technique is implemented by step-positioning of the needle-tip probe, located on the cross-sectional boundary of a parallel-plate layered structure. The spreading current pulsed measurements are performed by scanning the boundary of the structure using a needle-tip electrode. The other contact is connected to the parallel plate electrode at planar sample surface.
It has been revealed that even small deviations of density of impurities induced by technological high temperature double-diffusion processes lead to a crucial degradation of the device functioning. Anneal of the structures at moderate temperatures <500 °C allow suppressing of the impact of deep traps. It has been demonstrated that pulsed barrier evaluation by linearly increasing voltage (BELIV) technique was more sensitive tool for inspection of the barrier capacitance characteristics influenced by harmful impurities induced by heating based technological procedures. It is shown that junctions formed by diffusion procedures lead to an asymmetry of junction location within pnp structures. This can be a reason for a reduction of the blocking voltage in power device.