DESIGN AND INSTALLATION OF THE DOSIMETER VUTEG-5-AIDA AND CALIBRATION OF FLUENCE DEPENDENT VARIATION OF DEFECTS DENSITY

Arūnas Velička1, Aurimas Uleckas1, Tomas Čeponis1, Eugenijus Gaubas1

1 Institute of Applied Research, Vilnius University, Sauletekio Ave. 9-III, LT-10222 Vilnius, Lithuania

Operation of CERN Large Hadron Collider (LHC) results in production of the background radiation due to high energy proton or ion interaction with surrounding matter (magnets, collimators, pipes, etc). These events produce secondary particles that may be energetic enough to cause further interactions in form of particle showers. Such radiative environment is dangerous for the LHC machine controlling electronic devices that undergo two categories of damage effects: gradual and Single Event Effects (SEE) [1, 2]. Gradual effects in electronics are caused by creating or activating individual microscopic defects by deposition of Total Ionizing Dose (TID) and Non-ionizing Energy Loss (NIEL) induced displacement damage. Each individual defect does not significantly change characteristics of the device, nevertheless, accumulation of these defects leads to device degradation. SEEs are caused by single energetic particles by direct ionization or induction of nuclear reaction. The consequence of these may be corruption of data (eg. Single Event Latch-Up - SEL) or permanent damage of the device (eg. Single Event Upset - SEU). Furthermore, radiation is extremely dangerous for working personnel. Therefore, measurements of radiation levels are necessary for performing correct and human-safe experiments in the LHC machine.

The radiation detectors must fulfil challenging conditions that include prolonged operation time (10 years), different operating temperatures and variable intensity of particles with diverse range of energies [3]. These conditions are met by RadFET (Radiation-sensitive Field Effect Transistor) transistors and p-i-n diodes that are currently used as detectors in radiation dosimeters in the LHC machine [4].

The aim of this work is to propose non-invasive microwave-probed photoconductivity (MW-PCD) transient technique based VUTEG-5-AIDA dosimeter as an alternative approach for radiation measurements. The development of such dosimeter is a part of CERN FP7 AIDA project.

In this research analysis of excess carrier lifetime, dependent on fluence of reactor neutrons, accelerated protons and on dose of gamma rays, has been performed on MCZ Si n- and p-type material wafers and n-Si base p-i-n diodes. Calibrational measurement of fluence dependent excess carrier lifetime variations were carried out on different material and device structures by comparing non-capsulated and polyethylene bag capsulated samples.