APPLICATION OF LASER DIFFRACTOMERTY IN ANALYSIS OF CELLULAR SYSTEMS

Sophy Kavalenka1, Alena Kavalenka1, Vladislav Popov1, Valera Loban1

1 Department of Physics, Belarusian State University, Belarus

Laser diffractometry is an optical coherent method that allow to obtain important information about properties of the different particles including dispersed cellular systems such as blood or bone marrow cells and other [1-4]. The main advantages of laser diffraction method are the lack of contact, the ease to use, high accuracy, ability to automate the measurement. The basis of the method is the analysis of the light scattering patterns that are results of diffraction, refraction, reflection and absorption of laser light during the laser beam interaction with investigated particle/particles [5-7]. The angular dependence of light scattering intensity called the indicatrix is characteristic for the particle size. Therefore, laser diffractometry is the most widely applied for determination of cell sizes.

The ability to aggregate and the deformability during stimulated swelling of cells are studied to determine the key functional properties of blood cells and other, in particularly, erythrocytes, platelets, neutrophils and canser cells. These researches can be performed by laser diffraction method, too. Holographic digital microscope with semiconductor laser diode and CCD matrix was developed to obtain the 3D images of cells that restore by mathematical analysis of diffraction pictures.

The most often the Fraunhofer approximation or the Mie theory is used for transforming the measured data to a particle size distribution [5-7]. The use of Fraunhofer theory is suitable for large particles but the Mie theory provides the greatest accuracy for the small particle. It has been postulated that scattering events are independent and that total scattering is the sum of individual events. The use of Mie theory presupposes knowledge of the light refractive index of the particles and the dispersion media and the imaginary part of the refractive index of the particles [5-7]. It is important that if the refractive index of the sample and the dispersion media are the same, the laser beam can not be diffracted and this media should be changed. It is necessary to note the disadvantage that the accuracy of measurements for non-spherical particles is unacceptable [5,6]. The exact theory of scattering (Mie theory, T-matrix method, discrete dipole approximation method [5,8-10] and the approximate calculation methods [11] is used to calculate the indicatrix of a single particle. Suspensions of cells can be analyzed using the multi-mode Laplace transformation for detection and separation of multi-modal particle size distributions. The mathematical analysis of experimental data in [12] was perfomed with application neural network method.

The automated multi-channel laser analyzer for researches of cell structural changes during stimulation was developed in our laboratory (Faculty of Physics, Belarusian State University). Semiconductor laser diode LFD635-5-3 and high-sensitive opto-electronic integrated circuits OPT301 were used in this device as the laser light source and the scattered light intensity detectors, respectively. Microcontroller AtMega8535 provides the control of kinetic data registration and processing. Firmware for the microcontroller was written using Atmel AVR-Studio 6.0. As software UniChrom-97 ("New Analytical Systems", Belarus) was used. To support nephelometer driver DLL was developed using driver development kit UniChrom-DDK.


[1] E. Bedner, Laser scanning cytometry distinguishes lymphocytes, monocytes, and granulocytes by differences in their chromatin structure, Cytometry 29, 191–196 (1997)

[2] A.N. Shvalov, Light-scattering properties of individual erythrocytes, Appl. Optics 38, 230-235 (1999)

[3] M. Kalashnikov et al., Assessing light scattering of intracellular organelles in single intact living cells, Optics Express 17, 19674–19681 (2009)

[4] J. Mourant et al., Light scattering from cells: the contribution of the nucleus and the effects of proliferate status, J Biomed Opt. 5, 131-137 (2000)

[5] A. Doicu, T. Wriedt Computation of the beam-shape coefficients in the generalized Lorenz-Mie theory by using the translational addition theorem for spherical vector wave functions, Appl. Opt. 13, 2971–2978 (1997)

[6] F.M. Etzler, Particle-size analysis: a comparison of methods, American Pharm Review 7(1), 104-108 (2004)

[7] S.A. Kubart, K.M. Keck, Laser diffractometry of nanoparticles: frequent pitfalls and overlooked opportunities, J. Pharm. Technol. Drug Res., http://www.hoajonline.com/journals/pdf/2050-120X-2-17.pdf (2013)

[8] M.I., Mishchenko, et al., T-matrix computations of light scattering by nonspherical particles, J. Quant. Spectr. Rad. Transfer. 55, 535-575 (1996)

[9] P. Flatau, Fast solvers for one dimensional light scattering in the discrete dipole approximation, Opt. Express 12, 3149-3155 (2004)

[10] D.W. Mackowski, M.I. Mishchenko, Direct simulation of multiple scattering by discrete random media illuminated by Gaussian beams, Phys. Rev. A. 83(1), 013804-013814 (2011)

[11] P. Chiappetta, B. Torresani, Some approximate methods for computing elecromagnetic fields scattered by complex object, Measur. Sci. Technol., 9, 171-182 (1998)

[12] Z. Ulanowski, et al., Application of neural networks to the inverse light scattering problem for spheres, Applied Optics 37, 4027-4033 (1998)