Despite achievements in treatment of cardiovascular diseases, this pathology continues to remain the main reason of incidence and mortality in the world, annually carrying away 17 million lives. So, one of 8 men and one of 17 women in the world die of cardiovascular diseases to 65-year age. Thus in structure of diseases of system of blood circulation growth of an incidence by coronary heart disease and cerebrovascular pathology which in 91% of cases are the reasons of deadly outcomes from diseases of system of blood circulation among all population [1].
In the most perspective way of ultrasonic destruction of blood clots is ultrasonic thrombolysis which assumes introduction of an ultrasonic wave guide together with thrombolytic drugs (in particular, streptokinase) in a vessel with blood clot then, thanks to total influence of high-intensity ultrasound and preparation lysis, blood clot effectively collapses. And the ultrasound in this case, except mechanical cavitational influence, also considerably increases extent of penetration of a thrombolytic drug in blood clot [2].
Low-frequency high-intensity ultrasound causes changes in the structural and functional state of the blood cells and the vascular endothelium, as well as indicators of blood plasma coagulation, the severity of which depends on the parameters of ultrasonic treatment and head shape of the waveguide is used [3]. Among others, damage to vessel walls of the thrombus caused by the cavitation jet unfocused. In fact, damage to the vascular endothelium by ultrasound thrombolysis is one of the few remaining unsolved problems facing the widespread introduction of the method in clinical practice. The aim of this work is to develop a method of reducing damage to the vessel walls with ultrasound thrombolysis.
The study:
1) A modification of the method of ultrasound thrombolysis investigated: use of the magnetorheological fluid (colloidal solution containing fine particles (0.5 - 20 μm) oxide Fe (II, III) (magnetite), possessing the properties of the liquid and reacts to a magnetic field) as the immersion medium. The results of calorimetric experiments show that the cavitation threshold in magnetorheological fluid is lower than the cavitation threshold in blood, resulting in less energy needed for cavitation, which reduces damage to the vascular wall.
2) Three different magnetorheological fluid composition and the method of manufacture had developed (magnetorheological fluid based on saline, magnetorheological fluid based on dextran, magnetorheological fluid based on an aqueous solution of 10 % citric acid). Magnetorheological fluid showed an extremely high performance of bio neutrality: experiments in vitro on erythrocyte hemo neutrality and in vivo experiments on laboratory rats had conducted (intravenous injection of working volume of magnetorheological fluid (0.5 ml); blood tests and morphological studies of organs).
Currently studies destruction efficiency of fibrin clots in vitro by using a magnetorheological fluid as the immersion medium, further studies would be undertaken in vivo. Solution carrying fine particles of magnetite in the magnetorheological fluid is a great carrier for thrombolytic drugs. And thanks to the similarity of the size of cavitation bubbles formed and magnetite particles, the last transmitted more kinetic and thermal energy, which increases the degree of destruction of the fibrin clot net. Also, by the action of the toroidal magnetic field magnetorheological fluid, it is possible to change the shape of the immersion bridge between a thrombus and the waveguide so that the effect is realized for total internal reflection, i.e. almost all of the ultrasonic energy is directed into the thrombus, by which will be significantly reduced damage to the vascular wall. Among other things, when magnetite particles are in contact with the thrombus hyperthermia technique can be applied: the effects on the tissue with ferromagnetic particles of high-frequency magnetic field, the particles are heated by friction and break this tissue. When implementing the above described methods in this study, it is assumed optimal ultrasonic destruction of thrombus.