STABILITY AND INTENSITY OF SPECTRAL LINES IN HFEDLS WITH ZINC

Anda Svagere1, Rolands Zvejnieks1

1 Institute of Atomic Physics and Spectroscopy, University of Latvia

Covering the spectrum from the vacuum ultraviolet to the infrared, high-frequency electrodeless lamps (HFEDLs), due to their capability to emit high intensity narrow spectral lines, are widely used as emission sources in various experiments such as sensitized fluorescence experiments, measurements of the shifts, broadening of spectral lines, and scientific devices, for example, emission and absorption spectrometers, spectrometers for refractive index measurements and frequency standards. Also because of the lack of electrodes, that can cause impurities, HFEDLs are also very convenient for plasma-surface interaction studies [1].

Main requirements for such light sources are high intensity of spectral lines, long lifetime, emission stability and narrow and not self-absorbed line profiles. Of course, depending on the application, these requirements may vary, so it is necessary to optimize light sources for each particular use.

In this work we present measurements of HFEDLs containing zinc as working element and argon as buffer gas, developed in our laboratory for different analytical devices, particularly, atomic absorption spectrometers. We compared three diffrerent types of lamps – lamps filled with zinc with sideam, zinc lamps without sidearm and lamps filled with zinc and antimony iodine. Our aim was to see how changes in filling and lamp form influence behaviour of zinc and argon spectral lines.

During our research we investigated both intensity changes of spectral lines induced by change of generator voltage and stability of spectral line intensity during several hours of HFEDLs working time.

The emitted light spectra were registered using two different spectrometers - AVANTES AVS-PC2000 plug-in spectrometer with a 2048-element linear CCD-array detector in the wavelength range from 190 till 850 nm and Jobin Yvon SPEX 1000M in the range from 200 till 850 nm.

The results of our measurements showed that in order to achieve higher intensities of zinc spectral lines, lamps without sidearm or with addition of antimony iodine should be chosen. Lack of sidearm also provided better stability of zinc spectral lines.


[1] A. Skudra, Z. Gavare, N. Zorina, M. Zinge, E. Gavars, R. Poplausks, A. Svagere, Plasma Temperature and Surface Studies of Argon Hydrogen Containing Low-Temperature Dumbbell form Light Sources, Journal of Materials Science and Engineering B 1, 439-444(2011)