CALCULATION OF FORCES ACTING ON LEVITATING PYROLYTIC GRAPHITE ILLUMINATED BY LASER

Robertas Samavičius1, Virgilijus Minialga1

1 Department of Physics, Kaunas University of Technology

Diamagnetism is the property of a substance to induce a magnetic field opposite to the applied external magnetic field and thus be pushed in the direction of the weaker magnetic field. Pyrolytic graphite (PG) is a synthetic material with a structure much like of graphite. It has the strongest diamagnetic properties of all known materials at room temperature. Pyrolytic graphite and other diamagnetic materials are described by negative magnetic susceptibility χ. PG is anisotropic material, so its magnetic susceptibility value depends on crystallographic direction: perpendicular to the crystallographic planes χ⊥ = -450 · 10-6, parallel to the crystallographic planes χ|| = -85 · 10-6.

Pyrolytic graphite placed in magnetic field will levitate under certain conditions. Levitation height of diamagnetic material will depend on the material density, magnetic susceptibility and magnetic field. PG plate, illuminated by a laser beam, will change its magnetic susceptibility. This change will decrease levitation height of pyrolytic graphite. PG will move towards direction of laser illumination point if laser beam is directed towards the edge of the plate. This movement can be explained by the appearance of an unbalanced forces. The aim of this work was to calculate the forces acting on pyrolytic graphite. FEMM 4.2 software was used to calculate such forces. Using this software we simulated pyrolytic graphite levitation above neodymium magnet system comprising quad pole (Fig. 1). PG plate (thickness - 25 μm, diameter – 3 mm) is levitating 0.60 mm above four 500mT NdFeB magnets (3 mm x 3 mm x 10 mm). Changes of magnetic field at the plate edges were observed with the change of material magnetic susceptibility. Using this data the magnetic force dependence on temperature and unbalanced force magnitude was calculated.

Figure 1
Fig. 1. Simulation of pyrolytic graphite plate (PG) levitating above neodymium magnets (NdFeB) obtained by FEMM 4.2 software

Magnetic force acting on pyrolytic graphite depends on the magnetic susceptibility of PG which varies with changes in temperature. Different magnetic susceptibility values in the material causes appearance of unbalanced forces. Vertical unbalanced force acting on PG can be described as follows

$$\Delta F = \left(\frac{V \cdot (a \cdot \Delta T - b)}{\mu_0}\right) \cdot B \cdot \frac{dB}{dz},\tag{1}$$

where V is PG plate volume, ΔT is temperature difference at PG plate edges, coefficients a = 4.293 ∙ 10-7 1/K and b = 4,563 ∙ 10-4, μ0 = 1.26 ∙ 10-6 H/m, B is magnetic field induction at levitation height z, $\frac{dB}{dz}$ is magnetic field induction gradient at levitation height z.

Program FEMM 4.2 allows us to calculate magnetic field values around diamagnetic material, unbalanced forces increase linearly with increasing temperature difference on the different edges of PG plate.


[1] Masayuki Kobayashi, Jiro Abe., Optical Motion Control of Maglev Graphite, J. Am. Chem. Soc. (2012).

[2] FEMM 4.2, http://www.femm.info/wiki/HomePage (2015.01.25)