ALTERATION OF FUNCTIONAL ACTIVITY OF HUMAN BLOOD NEUTROPHILS AFTER EXPOSURE TO CONSTANT ELECTRIC FIELD WITH STRENGTH UP TO 1 V/SM

Elizaveta Kavalenka1, Artemiy Yushkevich1, Alena Kavalenka1

1 Department of Biophysics, Belarusian State University

Electromagnetic fields are increasingly used in medicine, physiotherapy, technologies for growing biological tissues, in cellular technologies for controlling the movement, functioning of cells and permeability of their membranes. Blood cells can be target cells to which the effect is directed, and they can be "companions" of other target cells in some tissues. Aim of the work was to study the change of morphological and functional characteristics of neutrophils after application of constant electric field with strength up to 1 V/sm.

Neutrophils were isolated from human blood by gradient centrifugation. Red blood cells were deleted by hypotonic lysis. Cells were suspended in Earle's salt balanced solution at pH 7,3.

Constant electric field was formed by parallel wire still electrodes using software controlled measurement stand which was developed in department of biophysics in BSU. It is necessary to note, that electric current in cell suspensions was not more than 10 mA at voltage 1 V between electrodes placed one from another at a distance of 1 sm. Cells were incubated under electric field during different time periods up to 1 hour.

Ability of cells to reactive oxygen (ROS) generation and secretion of enzymes were studied by chemiluminescence methods. The count and size of cells and cellular aggregates were investigated by light microscopy and light scattering methods. Activity of neutrophils was stimulated under adhesion of the cells to glass surface, action of chemoattractant fMLP and at phagocytosis of latex particles at 37 °C.

It was revealed that exposure of neutrophils to constant electric field with strength of 1 V/sm leads to the amplification of cell aggregation and release of myeloperoxidase from cells in extracellular medium. The significant cell destruction was not found. ROS generation at activation of the cells at adhesion, fMLP action and latex particles was strong altered after electric field exposure. The changes of kinetics of cell activation were established. Effects of constant electric field action on neutrophils depend on duration and strength of impact.

So, constant electric field with strength up to 1 V/sm is not cause strong destructive action on human blood neutrophils and leads to modulation of functional activity of the cells.