ON THE RELATION OF THE OUTDOOR AND INDOOR AEROSOL PARTICLE CONCENTRATION AT VILNIUS CITY ELEMENTARY SCHOOLS

Vadimas Dudoitis1, Nina Prokopčiuk1, Ulrich Franck2, Nikolaj Tarasiuk1, Vidmantas Ulevičius1, Daiva Čepuraitė3, Kęstutis Štaras4

1 SRI Center for Physical Sciences and Technology, Lithuania

2 Helmholtz-Centre for Environmental Research, Germany

3 Centro poliklinika, Lithuania

4 Vilnius City Municipal Public Health Bureau, Vilnius, Lithuania

Airborne particles are well known to produce detrimental effects on human health, and children are especially vulnerable to such environmental exposure [1]. During the classes grade-schoolers spend a significant amount of time indoors. The common sources of indoor aerosol are closely related to human personal activity [2, 3]. In order to evaluate indoor aerosol particle exposure among pupils at elementary schools, several schools from different Vilnius county district locations were selected. The aerosol particle number and mass concentrations (PNC and PMC) were measured both inside and outside of the studied buildings. Measurements of outdoor aerosol concentrations were carried out in order to study the influence of the outdoor environment upon the indoors, as well.

A condensation particle counter (CPC, TSI model 3007) was used for measuring aerosol total particle number concentration (PNC1) up to 10 nm of size. Optical particle sizer (OPS, TSI model 3330) was used for measuring aerosol particle size distribution in the range from 0.3 to 10.0 μm, PNC2 and PMC. The indoor measurements were conducted in the classrooms during the lessons and in the corridors during the lessons and lesson breaks. The typical measurement duration lasted for 10 min. In order to meet the specific technical requirements for CPC measurement outdoors (air temperature – above 10 °C and relative humidity – below 70%), the outdoor air was sucked through an open window into the room up to 3 min. The outdoor aerosol concentration levels were characterised by settling of these extreme values during the induced draught conditions.

During the 2017 autumn measurements, outdoor aerosol PNCs1 (measured by CPC), PNCs2 and PMCs (measured by OPS) varied in the ranges of 2600-17000 cm-3, 30-2890 cm-3 and 9-100 μg·m-3, respectively. Indoor aerosol PNCs1, PNCs2 and PMCs varied in the size range of 1800-24160 cm-3, 13-390 cm-3 and 12-274 μg m-3, respectively. The levels of indoor aerosol particle concentrations in schools were higher than the outdoor ones and were influenced by the aerosol particle sources inside the building, such as cooking activity in the canteen and school-graders activity in the corridors during the lesson breaks. Measurement areas inside the school can be ranked according to the highest PNC values at the dining room entrances (not in every school) reached up to 70000-77000 cm-3, in the corridors during the lesson breaks – up to 36000-44900 cm-3 and in the classrooms – up to 17000-24160 cm-3. The elevated levels of aerosol PNCs2 and PMCs was also depicted in the corridors during the lesson breaks and in the classrooms, equipped with soft furnishing and carpets. Indoor aerosol PNCs1 were more susceptible to the outdoor aerosol concentration increase in the elementary schools, located in the areas, exposed to a comparatively high level of outdoor air pollution.


[1] G. Buonanno, G. B. Marks, L. Morawska, Health effects of daily airborne particle dose in children: Direct association between personal dose and respiratory health effects, Environmental Pollution 180, 246–250 (2013).

[2] H. Guo, L. Morawska, C. He et al., Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air, Environmental Science and Pollution Research 17(6), 1268–1278 (2010).

[3] T. Hussein, T. Glytsos, J. Ondráček et al., Particle size characterization and emission rates during indoor activities in a house, Atmospheric Environment 40(23), 4285–4307 (2006).