ACCOMMODATION LAG UNDER MONOCULAR AND BINOCULAR CONDITIONS IN SYMPTOMATIC AND ASYMPTOMATIC EMMETROPES

Karola Panke1, Aiga Svede1, Wolfgang Jaschinski2, Gunta Krumina1

1 Department of Optometry and Vision Science, University of Latvia, Kengaraga 8, Riga, Latvia, LV-1063

2 Leibniz Research Centre for Working Environment and Human Factors (IfaDo), Research Group "Individual Visual Performance" Ardeystr. 67, D - 44139 Dortmund, Germany

Introduction: Accommodation is the focusing mechanism that provides fast changes in the optical power of the eye in order to keep the image clear when changing the gaze from far to near distance. For each distance there is a constant theoretical accommodative demand, but real accommodation response maintain slightly lower. Difference between accommodative demand and accommodation response is called accommodative lag. The purpose of this study was to estimate the relationship between accommodation lag under monocular and binocular conditions in symptomatic and asymptomatic groups.

Method: Twenty participants (emmetropes) with mean age 24 $ \pm $ 4 years participated in the study. Accommodative response was measured for dominant eye with open-field infrared autorefractometer (Shin-Nippon, SRW-5000) at 40 cm, 30 cm, and 24 cm (corresponding accommodative demands of 2.5D, 3.33D, and 4.17D) under monocular and binocular condition. Each accommodation measurement consisted of approximately 130 dynamic data points collected during consecutive 2 min time. Dissociated phoria for each distance was measured with Madox test. Convergence insufficiency symptom survey (CISS) score was used to distinguish symptomatic and asymptomatic group. Sequence of accommodation measurements were random order and all experiment was replicated twice within 7 $ \pm $ 2 days.

Results: The two measurement sessions resulted in a test-retest correlation of $r=0.95$ for accommodative response. To indicate reliability of accommodation response, we used the standard deviation of the difference between repeated measurements (0.22 D). For asymptomatic group, monocular accommodative lag differed significantly across the distances – from 40 cm to 30 cm (0.22 $ \pm $ 0.19 D, $p=0.028$) and from 40 cm to 24 cm (0.35 $ \pm $ 0.25 D, $p=0.006$) showing a tendency for accommodative lag to increase with closer distance (nonparametric ANOVA: $p = 0.025$). For symptomatic group, monocular accommodative lag differed in a similar way – from 40 cm to 30 cm (0.20 $ \pm $ 0.32 D, $p=0.02$) and from 40 cm to 24 cm (0.24 $ \pm $ 0.31 D, $p=0.02$). Binocular accommodation lag was significantly smaller than monocular accommodation lag (Spearman $r = 0.77$; $p < 0.001$).

Conclusions: At close working distances (40 cm and closer), accommodation tends to be more variable and inaccurate for symptomatic patients both for monocular and binocular viewing conditions.

Acknowledgments: This study is supported by ESF Project No.2013/0021/1DP/1.1.1.2.0/13/APIA/VIAA/001 and also funded by "Deutsche Forschungsgemeinschaft" (DFG JA 747/5-2)