INVESTIGATION OF SOLVENT-INDUCED SWELLING OF POLYPYRROLE THIN FILMS BY DRT ANALYSIS OF ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY DATA

Domas Pirštelis1, 2, Ernestas Brazys1, 2, Vilma Ratautaitė1, Arūnas Ramanavičius1, 2

1 Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, Sauletekio av. 3, Vilnius LT-10257, Lithuania

2 Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko str. 24, Vilnius LT-03225, Lithuania

Conducting polymers, such as polypyrrole(Ppy) are increasingly employed in modern bioelectronic devices [1]. However, their performance can be strongly affected by solvent induced swelling and the associated structural changes in the polymer matrix. One of the key challenges in such systems is therefore evaluating their robustness and stability in different media by characterizing the effect of pH, solvent or electrolyte-induced changes in the polymer matrix [2].

In this work, thin films of conducting polymer polypyrrole were electrochemically deposed onto screen printed carbon electrodes (SPCE). After synthesis, the Ppy/SPCE system was exposed to electrolyte solutions containing increasing concentrations of ethanol as a cosolvent. Fast Fourier transform electrochemical impedance spectroscopy (FFT-EIS) was applied to rapidly monitor time dependent changes in the electrochemical system.

For the analysis of the acquired EIS data, the two employed approaches were non-linear least squares fitting using equivalent circuit models and distribution of relaxation times (DRT) analysis [3]. Equivalent circuit model fitting provides information about changes in charge-transfer resistance, electric double-layer capacitance, and mass-transport limitations. In contrast, DRT analysis reveals dynamic shifts in the underlying relaxation processes of the Ppy/SPCE system without relying on a predefined equivalent circuit model. The combined data analysis provides valuable insights into ethanol-induced polymer swelling and reorganization of the Ppy film.

Acknowledgments: This research was supported by the Lithuanian Research Council under project No. S-MIP-24-111


[1] J. Sarvutiene, U. Prentice, S. Ramanavicius, and A. Ramanavicius, “Molecular imprinting technology for biomedical applications,” Mar. 01, 2024, Elsevier Inc. doi: 10.1016/j.biotechadv.2024.108318.

[2] E. Brazys, V. Ratautaite, E. Mohsenzadeh, R. Boguzaite, A. Ramanaviciute, and A. Ramanavicius, “Formation of molecularly imprinted polymers: Strategies applied for the removal of protein template (review),” Adv. Colloid Interface Sci., vol. 337, p. 103386, Mar. 2025, doi: 10.1016/J.CIS.2024.103386.

[3] T. H. Wan, M. Saccoccio, C. Chen, and F. Ciucci, “Influence of the Discretization Methods on the Distribution of Relaxation Times Deconvolution: Implementing Radial Basis Functions with DRTtools,” Electrochim. Acta, vol. 184, pp. 483–499, Dec. 2015, doi: 10.1016/J.ELECTACTA.2015.09.097.