Nonlinear refractive index (n2) describes how the refractive index of a medium depends on the intensity of light. This parameter is responsible for many phenomena of nonlinear optics and in modeling such phenomena it is important to know the most precise value of n2. Popular methods for measuring n2, like Z-scan [1], are based on the assumption that the temporal and spatial intensity distributions of the laser radiation are in the form of a Gaussian function. In practice this is sometimes difficult to fulfill, especially in the mid-infrared (MIR) wavelength range between 2µm and 20µm, where there is a shortage of information about n2. Therefore, n2 measurements, with included real spatial and temporal intensity distributions, are of great importance.
In this work we chose to measure n2 by using a Mach-Zehnder type interferometer to detect a total on-axis nonlinear phase shift B acquired in a sample and including measured spatial and temporal intensity distributions by numerically simulating the experiment. A simplified optical scheme of the measurement is shown in Fig. 1. For infrared light generation we used a label-free optical parametric amplifier (OPA), pumped by a femtosecond Yb:KGW laser (Pharos, Light Conversion). From the interference pattern we obtain a surface of spatial phase difference between two interfering waves (using Fourier transform method (FTM) [2]). To avoid the effects of linear wave front distortion and tilted pulse fronts we obtain a change of B (ΔB) from a change of two phase surfaces, corresponding to a different pulse energy. Here ΔB was found by fitting spatial intensity distribution (which can be in the form of any numerical function) of a beam at the sample to a phase difference surface.

We measured the effective n2 of some popular IR materials at different wavelengths λ and often using different polarization modes. The values of ΔB were measured at different pulse energy changes ΔE. Obtained ΔB values were corrected according to the measured pulse shape and the n2 was found from linearly fitted experimental data with a intercept value fixed at zero. Final results, along with a full list of measured materials, are presented in table 1.
| S/λ,μm | GaSe | AGS(o) | AGS(e) | ZGP(o) | ZGP(e) | BGSe | SBN-61 | KTA(o) | KTA(e) | LGS(o) | LGS(e) | Si | GaAs | ZnS | ZnTe | ZnSe | KRS-5 | KRS-6 | UVFS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.03 | - | - | - | - | - | - | 0.69 | 0.21 | 0.19 | 0.52 | 0.47 | - | - | 0.78 | - | 2.59 | - | - | 0.025 |
| 2.2 | 2.14 | 1.95 | 2.29 | 5.99 | 7.1 | 1.96 | 0.87 | 0.22 | 0.13 | - | 0.57 | 7 | - | 0.74 | 3.01 | 1.59 | 2.6 | 1.21 | - |
| 3.2 | 0.73 | 1.99 | 1.37 | 4.4 | 1.02 | 0.95 | 0.56 | 0.22 | 0.22 | 0.56 | 0.48 | 4.54 | 8.56 | 0.6 | 1.32 | 1.22 | 2.14 | 1.2 | - |
In conclusion, we measured effective nonlinear refractive index of some popular infrared materials in the spectral range from 1µm to 3µm with included real temporal and spatial intensity distributions.