APPLICATION OF POLY(FOLIC ACID) MODIFIED ELECTRODES FOR pH MONITORING

Vytautas Žutautas1, Tadas Jelinskas1, Rasa Pauliukaite1

1 Department of Nanoengineering, Center for Physical Sciences and Technology (FTMC), Savanoriu Ave. 231, LT-02300 Vilnius, Lithuania

Since a majority of chemical and biological processes are pH-dependent, its monitoring is an important research subject. Glass electrodes are widely used for this purpose nowadays as they have already been known since Max Cremer reported potentiometric pH measurement using glass membrane more than a hundred years ago [1]. However, glass electrodes have limited application in flat and flexible minimized device systems, moreover, they need calibration. Owing to this, a new type of pH sensor is required.

According to the literature, electrochemical redox processes of conducting polymers are frequently pH-dependent and due to this reason, they can be used for pH monitoring in a certain pH range [2]. Folic acid (FA), known as vitamin B9, is an electrochemically active heterocyclic redox compound with biological activity. It has been shown that FA can be polymerized electrochemically forming a conducting polymer poly(folic acid) (PFA) [3,4]. The application of PFA in the development of electrochemical sensors already has been reported, in particular, it was used for glucose detection [5].

In this, work, we used PFA deposited on pyrolytic graphite electrode (PGE) for pH determination in the range from 6 to 9. To prolong the stability of PFA during an extended exposition to slightly alkaline solutions, it was deposited on chitosan (Chit) modified PGE, since Chit is an environmentally friendly hydrogel polymer [6]. Resulted sensor PFA/Chit/PGE was characterized electrochemically and microscopically, and its response to pH was registered using chronoamperometry and potentiometry. The obtained results will be presented and discussed.

Acknowledgments: This work was supported by Lithuanian Research Council Grant No. 01.2.2-LMT-K-718-03-0038.


[1] F. Scholz, From the Leiden jar to the discovery of the glass electrode by Max Cremer, J. Solid State Electrochem. 15, 5-14 (2011).

[2] U. Lange, N.V. Roznyatovskaya, V.M. Mirsky, Conducting polymers in chemical sensors and arrays, Anal. Chim. Acta 614, 1–26 (2008).

[3] R. Pauliukaite, Application of natural polymers for electrochemical sensing, In "Biophysics for Biomedical and Environmental Sciences", ed. M. Florescu, Transilvania University of Brasov Press, Brasov 185-210 (2016).

[4] R. Celiešiūtė, T. Venckus, Š. Vaitekonis, R. Pauliukaite, Electrosynthesis and characterization of poly(folic acid) films, Electrochim. Acta 138, 62–68 (2014).

[5] T. Venckus, R. Celiešiūtė, A. Radzevič, T. Rakickas, Š. Vaitekonis, Ž. Ruelė, R. Pauliukaite, Application of polyfolates in the development of electrochemical glucose biosensors, Electroanalysis 26, 2273–2282 (2014).

[6] R. Pauliukaite, M.E. Ghica, O. Fatibello-Filho, C.M.A. Brett, Comparative study of different cross-linking agents for the immobilization of functionalized carbon nanotubes within a chitosan film supported on a graphite-epoxy composite electrode, Anal. Chem. 81, 5364–5372 (2009).