CROSS-CALIBRATION OF MULTISPECTRAL IMAGES OF BELARUSSIAN SATELLITE AND OTHERS AEROSPACE SYSTEM WITH ATMOSPHERIC CORRECTION

Volha Siliuk1, Leanid Katkouski1

1 Research Institute of Applied Physical Problems named after A.N.Sevchenko, Belarusian State University, Belarus

For extraction of information about the Earth surface from satellite data, it's necessary to do periodical check of satellite sensors stability. Cross-calibration of two or more sensors is one of the way of such check.

The Belarusian Satellite (BS) was launched in 2012. BS regularly takes pictures of the Earth surface, and this data are used for solving different problems. Cross-calibration of the data from BS and from other known satellites such as Landsat 8, EO-1 (ALI & Hyperion) and AVIRIS (airborne) was done [1,2]. The technique of the cross-calibration is described. The technique is based on calculation of correction factors that take into account the difference in band sensitivities of sensors and the differences in observing conditions (observation time). Cross-calibration techniques for multispectral and hyperspectral (AVIRIS, Hyperion) sensors have some features. These features are described.

Results of cross-calibration show that BS data are reliable enough because derived different sensors ratios of radiances measured quasi-synchronously above the same underlying surface are within the total uncertainties, determined by accuracy of absolute sensors calibrations. Calibration uncertainty of BS, Landsat 8, EO-1 and AVIRIS sensor is no more than 5% [3-6].

The performed technique isn't imply atmospheric correction of satellite data. It is considered that methods of cross-calibration with atmospheric correction are more reliable and accurate. Therefore, as a check on accuracy of the performed technique the cross-calibration of the same satellite data with atmospheric correction was done. For these, method of atmospheric correction is developing. The method are based on calculation of components of the radiative transfer equation by the code LibRadtran. The results of atmospheric correction by this method have a good correlation with results obtained by well-known module FLAASH of program ENVI.


[1] O Siliuk, L. Katkovsky. Inter-calibration of Belarusian Satellite with other imagers, Global Space-based Inter-Calibration System. Quarterly Newsletter: Fall Issue, V. 9, No. 3, 2016, p. 6-8.

[2] O. Siliuk, L.Katkovskii Methods and results of image cross-calibration of the Belarusian satellite and other sensors, V. 13, No. 4, 2016, p. 261-270.

[3] Belyaev, Y., et al., Spectral brightness passing schemes and methods of high-resolution and large aperture equipment calibration. The 10th all-Russia Open Conference "Current Problems in Remote Sensing of the Earth from Space", Book of Abstracts, 2012.

[4] Markham, B., et al., Landsat-8 Operational Land Imager Radiometric Calibration and Stability. Remote Sensing, Vol. 6, Issue 12, 12275-12308, DOI:10.3390/rs61212275, 2014.

[5] Mendenhall, J., Lencioni, D., Evans J., Spectral and Radiometric Calibration of the Advanced Land Imager. Lincoln Laboratory Journal, Vol. 15, No. 2, 2005, p 207-224.

[6] Chrien, T., et al., Calibration Validation of the AVIRIS Portable Radiance Standard. AVIRIS Workshop Proceeding, 2000,