NANOSECOND RESOLUTION CALORIMETRY USING DAYEM NANOBRIDGES

Marcin Bartmanski1, 2, Marek Foltyn2, Konrad Norowski1, 2, Maciej Zgirski2

1 Faculty of Physics, University of Warsaw, Poland

2 Institute of Physic Polish Academy of Sciences, Poland

The presentation will cover calorimetry of small metallic nanoislands - description of experimental setup and measuring protocol. The setup involves 2 normal metal reservoirs (e.g. Cu, Ag, Au) with a superconducting weak link in form of a Dayem nanobridge (Fig.1) in between them (Fig. 2). It allows to test the temperature of the reservoirs in the steady state (with a constant heating current applied) or in a transient (after heating has been switched off). The critical current of the bridge depends on temperature making junction perfectly suited for thermometry. By measuring changes in critical current I one can extract thermal dynamics of the reservoirs. Such an arrangement should be useful for studying electron-phonon thermal conductance G at a fixed temperature (steady state measurement), but more importantly, with the newly proposed protocol, addresses the nanosecond resolving measurement of electron-phonon thermal relaxation time te-p in a thin normal metal film. Since Te-p is the ratio of heat capacity C and G, time-domain measurement allows to determine the heat capacity of the reservoir. Such a calorimeter can be considered a basic block for constructing very fast and sensitive bolometers – detectors of electromagnetic radiation, especially in the infrared and terahertz bands.

Figure 1
Fig. 1. Dayem nanobridge obtaine with e-beam nanolithography
Figure 2
Fig. 2. Layout of calorimeter to be obtained with e-beam lithography