Shallow geothermal resources are widely utilized to meet a heat energy demands. Heat conductivity of geological structure is a paramount parameter to perform calculations of heat energy resource and draw up a design of the underground heat energy storage or extraction system before installation.
Estimation of heat conductivity of geological structure is time and cost requiring. The analysis of geological and geothermal data allows to perform a geothermal parameterisation of geological structure.
Complex of geological investigations were performed in 14 test fields. The depth of BHE varies from 14 to 180 m. The identification of the geological structure was performed by gathering the soil samples from the borehole during the drilling and the geophysical investigation logging data of the natural gamma and self-potential of the soils. The amount of sandy material varies from 11 to 64 %. Some of them contain separate marl, aleurite or dolomite layers Determination of the conductivity of geological structure was performed in – situ using a borehole heat exchanger (BHE). Estimated heat conductivity varies from 1.84 to 2.21 W/m*K [1].
After the statistical data processing it was found interdependences between the heat conductivity, lithological conditions and total depth of geological structure. Heat conductivity of sandy (more than 30 %) geological formations rises in average 0.94 present per each 10 m in the range of depth from 80 to 180 m. The interdependence between heat conductivity and lithological conditions is estimated with 89 % accuracy in investigated structures.
These results might be used for the predicting of the heat conductivity of geological structure by geological data. Allows us to create a conceptual model and calculate the amount of available underground heat energy resources.