CO-DOPED MANGANITE/GRAPHENE AS NEW PROTOTYPE FOR MAGNETIC FIELD SENSOR APPLICATION

Eleonora Bolli1, Alessio Mezzi1, Saulius Kaciulis1, Rasuole Lukose2, Nerija Zurauskiene2, 5, Voitech Stankevic2, 5, Milita Vagner2, 3, Valentina Plausinaitiene2, 3, Skirmantas Kersulis2, Gediminas Niaura4, Saulius Balevicius2, 5

1 Institute for the Study of Nanostructured Materials, ISMN-CNR, 00015 Rome, Italy

2 Department of Material Science and Electrical Engineering, Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania

3 Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT- 03225 Vilnius, Lithuania.

4 Department of Organic Chemistry, Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania

5 Department of Electrical Engineering, Vilnius Gediminas Technical University, LT- 10223 Vilnius, Lithuania.

[email protected]

Co-doped La1-xSrxMnyO3 manganite with single or few layer graphene is a novel system designed for magnetic sensor application at room temperature. Manganite/graphene structure combines the properties of manganite with negative magnetoresistance (MR) and two-dimensional graphene with positive MR in order to increase the sensitivity of sensor based on magnetoresistence also in the presence of low magnetic field, in the range 0.1-21 T.

The properties of Co-doped La1-xSrxMnyO3 with single layer graphene SLG, three-layer 3LG or five layer 5LG, were characterized by using X-ray photoemission spectroscopy (XPS) and Auger electron spectroscopy (XAES). XPS studies were focused on the analysis of photoemission C1s spectra of graphene layer, whereas the Auger spectra of C KVV region were used for determination of the D parameter [1].

Because this prototype of new device was prepared by exfoliating commercial high-quality monolayer graphene on Cu previously passivated with polymethylmethacrylate PMMA, from the component analysis of C1s spectra was possible to identify also the presence of polymer residues which could negatively affect the sensitivity to the magnetic field.

Magnetoresistance measurements of the sensors assembled with single and few layer graphene in permanent and pulsed magnetic fields have shown that the best sensitivity response is obtained for 3LG samples. This result was in accordance with XPS and XAES data, which revealed a better quality of 3L graphene with lower content of residues due to exfoliation process.


[1] S. Kaciulis, A. Mezzi, P.Calvani, D.M. Trucchi, Electron spectroscopy of the main allotropes of carbon. Surf. Interface Anal. 46 (2014) 966-969.