SUB-MICROSECOND RISE TIME MAGNETIC FIELD PULSER FOR BIOLOGICAL MAGNETOTRANSFER EXPERIMENTS

Gediminas Staigvila1, 2, Vitalij Novickij1, 2

1 Department of Electrical Engineering, Vilnius Gediminas Technical University, Lithuania

2 Institute of High Magnetic Fields,, Vilnius Gediminas Technical University, Lithuania

[email protected]

The emerging contactless cell membrane permeabilization methodology (magnetoporation), which is based on high pulsed magnetic field (PMF) is highly dependent on the applied pulse parameters. In order to trigger PMF induced cell permeabilization, magnetic field in the range of 3-6 T and the induced electric field in the range of 5-10 V/cm are required [1,2]. As a result, high dB/dt systems are advantageous [3,4].

In this work, a high dB/dt generator, which is applicable for magnetoporation or study of the biological effects of PMF has been developed and is presented. The generator is based on an ignitron switch (20 kV, up to 100 kA) and an array of silicon controlled rectifiers (SCR). The SCRs, as the main pulse forming switches (typical in PMF generation technology) are no longer suitable for the task due to the dI/dt and dV/dt ratings of the setup, therefore, ignitron is used for the output pulse forming.

The photograph of the generator and the output waveform are shown in Fig. 1.

Figure 1
Fig. 1. The photo of the generator and the output waveform

The ignitron switch due its superb current handling capability allowed using both the nearly short-circuit and highly inductive loads. To present the concept we have used merely 5% of the current handling capability of the generator. The structure, the waveforms and the step by step development process will be presented in the conference, while the results may find direct application as a platform for basic magnetoporation experiments.


[1] S. Kranjc, M. Kranjc, J. Scancar, J. Jelenc, G. Sersa, and D. Miklavcic, "Electrochemotherapy by pulsed electromagnetic field treatment (PEMF) in mouse melanoma B16F10 in vivo," Radiol. Oncol., 50, 39-48 (2016).

[2] V. Novickij, J. Dermol, A. Grainys, M. Kranjc, and D. Miklavčič, "Membrane permeabilization of mammalian cells using bursts of high magnetic field pulses," PeerJ, 5, e3267 (2017).

[3] J. W. M. Van Bree, J. J. G. Geysen, E. J. M. Van Heesch, and A. J. M. Pemen, "Novel nanosecond pulsed electric field device for noncontact treatment of cells in native culture conditions," IEEE Trans. Plasma Sci., 41, 2654-2658 (2013).

[4] V. Novickij et al., "Membrane Permeabilization of Pathogenic Yeast in Alternating Sub-microsecond Electromagnetic Fields in Combination with Conventional Electroporation," J. Membr. Biol., 251, 189-195 (2017).